Safety Footwear Standards Explained: EN ISO 20345 Codes, Slip Ratings and Markings
What does the code on my safety boot mean?
Every marked pair carries a class code. Add the extra letters and you can read the whole marking. For example S3S SR reads as: class S3, sole puncture protection of type S, and slip resistance SR.
What do SB, S1, S2, S3, S4, S5, S6 and S7 mean?
EN ISO 20345 sorts safety footwear into marking categories. Each category builds on the one before it. Class I is footwear made from leather and other materials; Class II is all-polymeric or all-rubber footwear. S6 and S7 were added in 2022.

| Category | Plain English | Technical requirement (as stated in Table 20) |
|---|---|---|
| SB | Basic safety footwear with a protective toe cap. | Basic requirements (Class I or II). Toecap protects against impact of at least 200 J and compression of at least 15 kN. |
| S1 | SB plus a closed heel, cushioning in the heel and antistatic properties. | Class I. As SB, plus closed heel area, energy absorption of seat region, antistatic. |
| S2 | S1 plus a water-resistant upper. | Class I. As S1, plus water penetration and absorption. |
| S3 | S2 plus sole puncture protection and a cleated sole. | Class I. As S2, plus perforation resistance (type P, PL or PS) and cleated outsole. |
| S4 | Rubber or polymer boot with the S1 protections. | Class II. As SB, plus closed heel, energy absorption, antistatic. |
| S5 | S4 plus sole puncture protection and a cleated sole. | Class II. As S4, plus perforation resistance and cleated outsole. |
| S6 | S2 plus the whole shoe tested as water resistant. | Class I. As S2, plus water resistance of the whole footwear. |
| S7 | S3 plus the whole shoe tested as water resistant. | Class I. As S3, plus water resistance of the whole footwear. |

What do P, PL and PS (the L and S in S3L and S3S) mean?
These show the type of sole puncture protection. P is a metal insert, which must withstand a force of not less than 1,100 N. PL is a non-metallic insert: in the test no perforation may occur at any of four measurements and the layers must not separate. PS is a non-metallic insert: the average force must be at least 1,100 N and no single value below 950 N, and the layers must not separate. So S3 is metal insert type P, S3L is non-metal type PL and S3S is non-metal type PS.
What does SR mean? What happened to SRA, SRB and SRC?
Under the earlier edition footwear was marked SRA (ceramic tile with soap solution), SRB (smooth steel with glycerol) or SRC (both). The 2022 edition deleted SRA, SRB and SRC and introduced SR and Ø.
- Basic test, no mark: a ceramic tile wetted with dilute soap (sodium lauryl sulphate) solution, tested at the heel and the forepart. Minimum friction: 0.31 forward heel slip and 0.36 backward forepart slip.
- SR: an optional extra test on ceramic tile with glycerine. Minimum friction: 0.19 forward heel slip and 0.22 backward forepart slip. The standard describes this as a generic test for more viscous contaminants such as oil and notes that it is particularly demanding.
- Ø: "not tested". Used for special-purpose footwear with spikes or metal studs for soft ground such as sand, sludge or forestry timber.

The standard also notes that neither test mimics heavy or loose ground outdoors, and that no footwear can give complete safety on spillages such as cooking or mineral oil. The HSE gives practical advice that applies whichever code you see: "oil-resistant" does not mean "slip-resistant", test surfaces are not representative of every floor, and footwear should be trialled in your own workplace.
What do the extra markings mean?
| Marking | Plain English | Technical requirement |
|---|---|---|
| C | Partially conductive footwear | Electrical resistance not greater than 100 kΩ. |
| A | Antistatic footwear | Resistance above 100 kΩ and up to 1,000 MΩ. |
| E | Energy absorption of the seat region | Not less than 20 J. |
| HI | Heat insulation of the sole | Temperature rise on the insole surface not higher than 22 °C after 30 minutes on a 150 °C plate. |
| CI | Cold insulation of the sole | Temperature decrease on the insole surface not more than 10 °C. |
| WR | Water resistance of the whole footwear | No water penetration inside the footwear detected in the test. |
| WPA | Water penetration and absorption of the upper (replaces WRU) | Water penetration not higher than 0.2 g and water absorption not more than 30%. |
| M | Metatarsal protection | Minimum clearance after impact set by shoe size (Table 17). |
| AN | Ankle protection | Outer ankle protection: average transmitted force not above 10 kN and no single value above 15 kN; the same applies if inner ankle protection is claimed. |
| CR | Cut resistance | Cut-resistance index not less than 2.5. |
| SC | Scuff cap, protects the toe area when kneeling | No hole through the full thickness before 8,000 abrasion cycles. Amendment 1 adds that, when worn while kneeling, the scuff cap must prevent contact between the upper and flat ground. |
| HRO | Resistance to hot contact | Outsole must not melt or crack when bent in the test. |
| FO | Resistance to fuel oil | Outsole volume increase not greater than 12%. |
| LG | Ladder grip | Transverse cleats at least 1.5 mm high in the waist area, with a defined heel breast. |
What changed between EN ISO 20345:2011 and 2022?
- New classes S6 and S7.
- SRA, SRB and SRC deleted; SR and Ø introduced; slip-resistance requirement revised.
- WRU deleted and WPA introduced.
- New optional markings: SC (scuff cap abrasion) and LG (ladder grip).
- Toe protection and perforation-resistant inserts now refer to ISO 22568 parts 1 to 4 instead of EN 12568.
- Information on obsolescence date added, and the requirement for electrically insulating footwear (EN 50321) removed.
- Test methods updated to EN ISO 20344:2021. Amendment A1:2024 followed on 29 Feb 2024 with technical corrections: for example a kneeling check for the scuff cap, a chromium VI limit of 3.0 mg/kg for leather parts, revised water vapour permeability rules for uppers, and clearer insole and outsole requirements.
Footwear certified to the 2011 edition is not suddenly invalid. Whether a given pair is certified to the 2011 or the 2022 edition is shown in its own marking and datasheet. That is why both codes still appear in the market.
UKCA, CE and what you must check
HSE states that most new PPE placed on the GB market must be UKCA or CE marked, and must come with a declaration of conformity and English instructions. Employers must still risk assess to decide what footwear is needed.